Type = 0 = daqTest, Major type = 0 = daq Used for run type development; versions undefined Type = 16 = crcTest, Major type = 1 = crc Used for run type development; versions undefined Type = 17 = crcNoise, Major type = 1 = crc Read out pedestals and noise Version controls trigger used and data read out Bits 0-1 - 0 use backplane-distributed software trigger 1 use BE software trigger 2 use FE broadcast trigger 3 use FE individual triggers Bit 2 - Enable VME block data transfer for ADC data Bits 3-7 - Readout event period for VME, FE and BE trigger data via slow link. Readout is done only for one event in every period Type = 18 = crcBeParameters, Major type = 1 = crc Type = 19 = crcFeParameters, Major type = 1 = crc Type = 20 = crcIntDac, Major type = 1 = crc Type = 21 = crcIntDacScan, Major type = 1 = crc Type = 22 = crcExtDac, Major type = 1 = crc Type = 23 = crcExtDacScan, Major type = 1 = crc Type = 24 = crcFakeEvent, Major type = 1 = crc Type = 32 = trgTest, Major type = 2 = trg Used for run type development; versions undefined Type = 33 = trgReadout, Major type = 2 = trg Type = 34 = trgParameters, Major type = 2 = trg Type = 35 = trgNoise, Major type = 2 = trg Type = 36 = trgSpill, Major type = 2 = trg Type = 48 = emcTest, Major type = 3 = emc Used for run type development; versions undefined Type = 49 = emcNoise, Major type = 3 = emc Read out pedestals and noise Version controls trigger used and data read out Bits 0-1 - 0 use backplane-distributed software trigger 1 use BE software trigger 2 use FE broadcast trigger 3 use FE individual triggers Bit 2 - Enable VME block data transfer for ADC data Bits 3-7 - Readout event period for VME, FE and BE trigger data via slow link. Readout is done only for one event in every period Type = 50 = emcVfeDac, Major type = 3 = emc Type = 51 = emcVfeDacScan, Major type = 3 = emc Type = 52 = emcVfeHoldScan, Major type = 3 = emc Type = 53 = emcBeam, Major type = 3 = emc Type = 54 = emcBeamHoldScan, Major type = 3 = emc Type = 55 = emcCosmics, Major type = 3 = emc Type = 56 = emcCosmicsHoldScan, Major type = 3 = emc Type = 64 = ahcTest, Major type = 4 = ahc Used for run type development; versions undefined Type = 65 = ahcDacScan, Major type = 4 = ahc Scans HAB DACs around their nominal values Configuration 0 - nominal Configuration 1 - nominal+1 Configuration 2 - nominal-1 Configuration 3 - nominal+2 Configuration 4 - nominal-2 Configuration 5 - nominal+3, etc Run end resets DACs to nominal value Version number gives maximum difference from nominal, so v=0 does DAC reset only, i.e. 1 configuration, v=1 does 3 configurations, etc. Type = 66 = ahcCmNoise, Major type = 4 = ahc Read out pedestals and noise in calib mode Version controls trigger used and data read out Bits 0-1 - 0 use backplane-distributed software trigger 1 use BE software trigger 2 use FE broadcast trigger 3 use FE individual triggers Bit 2 - Enable VME block data transfer for ADC data Bits 3-7 - Readout event period for VME, FE and BE trigger data via slow link. Readout is done only for one event in every period. A value of zero means never read these data. A typical use would be v=5, i.e. BE software trigger, fast ADC read and no slow links reads. Type = 67 = ahcPmNoise, Major type = 4 = ahc Read out with no signals in physics mode Version is the same as for ahcCmNoise Type = 68 = ahcAnalogOut, Major type = 4 = ahc Inhibit HOLD and allow partial multiplex sequence to see analogue output of single channel. Tcalib, Vcalib and LEDs are enabled. Version controls channel number and mode Bits 0-4 - Channel number Bit 5-6 - Unused Bit 7 - 0 is calib mode, 1 is physics mode Type = 69 = ahcCmAsic, Major type = 4 = ahc Reads out ASIC calibration signals in calib mode Version controls Vcalib value Bits 0-5 - 64*value gives Vcalib DAC value; max is 4032 Bit 6 - Disable Vcalib to board A Bit 7 - Disable Vcalib to board B Type = 70 = ahcCmAsicVcalibScan, Major type = 4 = ahc Scan Vcalib to see ASIC calibration signals in calib mode Configurations alternate Vcalib on boards A and B. Version controls number of steps taken to cover Vcalib DAC range 0-4095. The number of steps for each of board A and B is v+1, with the step size therefore being 4096/(v+1) Type = 71 = ahcCmAsicHoldScan, Major type = 4 = ahc Scan Hold to see ASIC calibration signals in calib mode. Version controls number of steps taken to cover Hold range 0-255. The number of steps is v+1, with the step size therefore being 256/(v+1) Type = 72 = ahcPmAsic, Major type = 4 = ahc Reads out ASIC calibration signals in physics mode Version controls Vcalib value Bits 0-5 - 128*value gives Vcalib DAC value; max is 8064 Bit 6 - Disable Vcalib to board A Bit 7 - Disable Vcalib to board B Type = 73 = ahcPmAsicVcalibScan, Major type = 4 = ahc Scan Vcalib to see ASIC calibration signals in physics mode Configurations alternate Vcalib on boards A and B. Version controls number of steps taken to cover Vcalib DAC range 0-8191. The number of steps for each of board A and B is v+1, with the step size therefore being 8192/(v+1) Type = 74 = ahcPmAsicHoldScan, Major type = 4 = ahc Scan Hold to see ASIC calibration signals in physics mode. Version controls number of steps taken to cover Hold range 0-511. The number of steps is v+1, with the step size therefore being 512/(v+1) Type = 75 = ahcCmLed, Major type = 4 = ahc Reads out LED calibration signals in calib mode Version gives Vcalib DAC value as 256*v; max is 65280 Type = 76 = ahcCmLedVcalibScan, Major type = 4 = ahc Scan Vcalib to see LED calibration signals in calib mode Version controls number of steps taken to cover Vcalib DAC range 0-65535. The number of steps is v+1, with the step size therefore being 65536/(v+1) Type = 77 = ahcCmLedHoldScan, Major type = 4 = ahc Scan Hold to see LED calibration signals in calib mode. Version controls number of steps of size 1 taken above a Hold of 70 so the Hold range is 70 to 70+v inclusive Type = 78 = ahcPmLed, Major type = 4 = ahc Reads out LED calibration signals in physics mode Version gives Vcalib DAC value as 256*v; max is 65280 Type = 79 = ahcPmLedVcalibScan, Major type = 4 = ahc Scan Vcalib to see LED calibration signals in physics mode Version controls number of steps taken to cover Vcalib DAC range 0-65535. The number of steps is v+1, with the step size therefore being 65536/(v+1) Type = 80 = ahcPmLedHoldScan, Major type = 4 = ahc Scan Hold to see LED calibration signals in physics mode. Version controls number of steps of size 2 taken above a Hold of 70 so the Hold range is 70 to 70+2*v inclusive Type = 81 = ahcScintillatorHoldScan, Major type = 4 = ahc Scan the Hold while pulsing the LEDs in the scintillator trigger as well as the detector. The version number is not used. Type = 82 = ahcBeam, Major type = 4 = ahc Type = 83 = ahcBeamHoldScan, Major type = 4 = ahc Type = 84 = ahcBeamStage, Major type = 4 = ahc Type = 85 = ahcBeamStageScan, Major type = 4 = ahc Type = 86 = ahcCosmics, Major type = 4 = ahc Type = 87 = ahcCosmicsHoldScan, Major type = 4 = ahc All beam and cosmics runs use the version number to control the trigger used during the data taking configuration (every third configuration) Bits 0-6 - Unused Bit 7 - 0 use real trigger 1 use oscillator trigger Type = 96 = dhcTest, Major type = 6 = dhc Used for run type development; versions undefined Type = 97 = dhcNoise, Major type = 6 = dhc Type = 98 = dhcBeam, Major type = 6 = dhc Type = 112 = tcmTest, Major type = 7 = tcm Used for run type development; versions undefined Type = 113 = tcmNoise, Major type = 7 = tcm Type = 128 = bmlTest, Major type = 8 = bml Used for run type development; versions undefined Type = 144 = slowTest, Major type = 9 = slow Used for run type development; versions undefined Type = 145 = slowMonitor, Major type = 9 = slow Type = 160 = beamTest, Major type = 10 = beam Used for run type development; versions undefined Type = 161 = beamNoise, Major type = 10 = beam Type = 162 = beamData, Major type = 10 = beam Type = 163 = beamHoldScan, Major type = 10 = beam Type = 164 = beamStage, Major type = 10 = beam Type = 165 = beamStageScan, Major type = 10 = beam All beam and cosmics runs use the version number to control the trigger used during the data taking configuration (every third configuration) Bits 0-6 - Unused Bit 7 - 0 use real trigger 1 use oscillator trigger Type = 176 = cosmicsTest, Major type = 11 = cosmics Used for run type development; versions undefined Type = 177 = cosmicsNoise, Major type = 11 = cosmics Type = 178 = cosmicsData, Major type = 11 = cosmics Type = 179 = cosmicsHoldScan, Major type = 11 = cosmics All beam and cosmics runs use the version number to control the trigger used during the data taking configuration (every third configuration) Bits 0-6 - Unused Bit 7 - 0 use real trigger 1 use oscillator trigger